Model No.︰XXQ/XXG/XXH
Brand Name︰Aolong
Country of Origin︰China
Unit Price︰-
Minimum Order︰1 pc
XXH-2005 X-ray Flaw Detection Of Welds equipped with the seletcted 200 kV glass X-ray insert with the beam angle of 30 × 360 ° and 25 × 360 ° option. Under the working voltage of 200kV and focal distance of 600mm, the 200kv x-ray Detection can penetrate 27mm Q235 steel.
X-ray flaw detection of Welds is an inspection method that uses X-ray to penetrate metal materials and forms images with different blackness on the film due to the different absorption and scattering effects of materials on the ray, thus judging the internal defects of materials.
XXH-2005 200kv x-ray Detection can be divided into directional radiation and Panoramic radiation.
The directional radiation is fixed and the cone Angle of the radiation beam is generally between 40° and 45°.
The Panoramic beam radiates X-rays simultaneously on a 360° circle perpendicular to the axis of the X-ray tube.
For the detection of annular weld of large diameter pipe fittings and spherical vessel, the whole weld can be detected by one exposure, thus greatly improving the detection efficiency.
WORKING PRINCIPLE
This XXH-2005 x-ray Detection is composed of intelligent controller x-ray generator, power cable and connecting cable.
1.The controller will consist of the following sections:
Front Panel: LED display, status and failure indicator, touch keyboards (see the introduction of control panel)
Side Panel: power cable socket and connecting cable socket, power switch,key switch, fuse socket, warning lamp and wire connecting terminal of door-machine interlock.
Internal Circuit: power circuit, rectifying circuit, filter circuit, inverter circuit, control circuit and other circuited.
2.The x-ray generator will consist of the following sections:
X-ray tube, High voltage transformer, Temperature relay, Gas pressure gauge and Cooling fan etc.
Specifications
Panoramic Portable X-ray Flaw Detector (with ceramic X-ray tube)
Model | Output
Voltage (kv) |
Input
(kw) |
Focus
(mm) |
Beam Angle | Q235 Max.
Penetration(mm) |
Weight of
Generator(kg) |
Dimension of
Generator(mm) |
||
Cone Target | Flat Target | Cone Target | Flat Target | ||||||
XXGH-2005 | 100~200 | 2.0 | 1.0×3.5 | 30×360° | 25×360° | 24 | 27 | 31 | 290×615 |
XXGH-2505 | 150~250 | 2.5 | 1.0×2.4 | 30×360° | 25×360° | 34 | 37 | 35 | 325×705 |
XXGH-3005 | 170~300 | 3.0 | 1.0×2.3 | 30×360° | 25×360° | 44 | 47 | 43 |
245×715
|
Panoramic Portable X-ray Flaw Detector (with glass X-ray tube)
Model | Output
Voltage (kV) |
I(kw) | Focus Size
(mm) |
Beam Angle | Q235 Max.
Penetration(mm) |
Weight of
Generator(kg) |
Dimension of
Generator(mm) |
||
Cone Target | Flat Target | Cone Target | Flat Target | ||||||
XXH-1005 | 60~100 | 1.2 | 1.0×3.5 | 30×360° | 25×360° | 4 | 6 | 11.1 | 190×530 |
XXH-1605 | 80~160 | 1.5 | 1.0×3.5 | 30×360° | 25×360° | 12 | 15 | 15 | 225×585 |
XXH-2005 | 100~200 | 2.0 | 1.0×3.5 | 30×360° | 25×360° | 24 | 27 | 21.5 | 285×665 |
XXH-2505 | 150~250 | 2.5 | 1.0×2.4 | 30×360° | 25×360° | 34 | 37 | 33.5 | 320×730 |
XXH-3005 | 170~300 | 3.0 | 1.0×2.3 | 30×360° | 25×360° | 44 | 47 | 40 | 345×830 |
XXH-3205 | 180~320 | 3.2 | 1.0×5.0 | 30×360° | 25×360° | 45 | 50 | 40 | 345×830 |
XXH-3505 | 180~350 | 3.4 | 1.0×5.0 | 30×360° | 25×360° | 52 | 55 | 42.6 |
345×830
|
Directional Portable X-ray Flaw Detector (with glass X-ray tube)
Model | Output Voltage
(kV) |
Input
(kw) |
Focus Size
(mm) |
Beam Angle | Q235 Max.
Penetration(mm) |
Weight of
Generator(kg) |
Dimension of
Generator(mm) |
XXQ-1005 | 60~100 | 1.2 | 0.8×0.8 | 40° | 8 | 11.1 | 190×530 |
XXQ-1605 | 80~160 | 1.5 | 0.8×0.8 | 40° | 19 | 15.2 | 225×585 |
XXQ-2050 | 100~200 | 2.0 | 1.5×1.5 | 40+5° | 30 | 23 | 285×665 |
XXQ-2505 | 150~250 | 2.5 | 2.0×2.0 | 40+5° | 40 | 35 | 320×730 |
XXQ-3005 | 170~300 | 3.0 | 2.3×2.3 | 40+5° | 50 | 45.5 | 345×830 |
XXQ-3205 | 180~320 | 3.2 | 2.5×2.3 | 40+5° | 55 | 45.5 | 345×830 |
XXQ-3505 | 180~350 | 3.4 | 2.8×3.0 | 40+5° | 60 | 47 | 345×800 |
Directional Portable X-ray Flaw Detector (with ceramic X-ray tube)
Model | Output Voltage
(kV) |
Input
(kw) |
Focus Size
(mm) |
Beam Angle | Q235 Max.
Penetration(mm) |
Weight of
Generator(kg) |
Dimension of
Generator(mm) |
XXG-1605 | 80~160 | 1.5 | 0.8×0.8 | 40+5° | 19 | 14.5 | 225×550 |
XXG-2005 | 100~200 | 2.0 | 2.0×2.0 | 40+5° | 30 | 18 | 285×615 |
XXG-2505 | 150~250 | 2.5 | 2.0×2.0 | 40+5° | 40 | 30.5 | 320×640 |
XXG-3005 | 170~300 | 3.0 | 2.5×2.5 | 40+5° | 50 | 36.5 | 345×670 |
XXG-3505 | 180~350 | 3.5 | 2.5×2.5 | 40+5° | 60 | 38 | 345×670 |
Panoramic Portable X-ray Flaw Detector (with glass X-ray tube)
Model Output Input (kw) Foucus(mm) Beam angle Max. penetration Generator (kg) Dimension (mm)
XXH-1005 60~100 1.2 1.0×3.5 25×360° 6 11.1 φ190×530
XXH-1605 80~160 1.5 1.0×3.5 25×360° 15 15 φ225×585
XXH-2005 100~200 2.0 1.0×3.5 25×360° 27 21.5 φ285×665
XXH-2505 150~250 2.5 1.0×2.4 25×360° 37 33.5 φ320×730
XXH-3005 170~300 3.0 1.0×2.3 25×360° 47 40 φ345×830
Panoramic Portable X-ray Flaw Detector (with ceramic X-ray tube)
Model Output Input Foucus Beam angle Max. penetration Generator Dimension (KV) (kw) (mm) (mm) (kg) (mm)
XXH-2005 100~200 2.0 1.0×3.5 25×360° 27 31 φ290×615
XXH-2505 150~250 2.5 1.0×2.4 25×360° 37 35 φ325×705
XXH-3005 170~300 3.0 1.0×2.3 25×360° 47 43 φ245×715
Panoramic Portable X-ray Flaw Detector (with ceramic X-ray tube)
Model Output Input (kw) Foucus(mm) Beam angle Max. penetration Generator (kg) Dimension
(KV) (kw) (mm) (mm) (kg) (mm)
XXGH-2005 100~200 2.0 1.0×3.5 25×360° 27 31 φ290×615
XXGH-2505 150~250 2.5 1.0×2.4 25×360° 37 35 φ325×705
XXGH-3005 170~300 3.0 1.0×2.3 25×360° 47 43 φ245×715
Convincing inspection solition supplier
More than 50 years, Aolong Group focuses on the Non-destructive Testing Technologies and gives our customers the best inspection solution with the high quality radiographic equipment with simple operation and complete functions.
Global non-destructive testing service pioneer
Our industrial X-ray equipment have been sold to over 60 countries and built our agents and after sale service centers in Europe, U.S, Africa and Asia. We can supply both high quality products and good after sale service.
Packing details
Each product will be packed in cartons or wooden cases (we also accept customers' demands)
Delivery time
1. For sample order, 3-5 working days
2. For mass production, 5-7 weeks (It also depends on the order quantity and design)
Price Terms︰ FOB SHANGHAI
Payment Terms︰ TT / LC / DP / DA
Packing︰ export package
Lead Time︰ 7 days
Standards Certificate︰ CE/ ISO